11 research outputs found

    Multi-task Implementation for Image Reconstruction of an AER Communication

    Get PDF
    Address-Event-Representation (AER) is a communication protocol for transferring spikes between bio-inspired chips. Such systems may consist of a hierarchical structure with several chips that transmit spikes among them in real time, while performing some processing. There exist several AER tools to help in developing and testing AER based systems. These tools require the use of a computer to allow the processing of the event information, reaching very high bandwidth at the AER communication level. We propose to use an embedded platform based on multi-task operating system to allow both, the AER communication and the AER processing without a laptop or a computer. We have connected and programmed a Gumstix computer to process Address- Event information and measured the performance referred to the previous AER tools solutions. In this paper, we present and study the performance of a new philosophy of a frame-grabber AER tool based on a multi-task environment, composed by the Intel XScale processor governed by an embedded GNU/Linux system.Ministerio de Ciencia e Innovación TEC2006-11730-C03-0

    AER and dynamic systems co-simulation over Simulink with Xilinx System Generator

    Get PDF
    Address-Event Representation (AER) is a neuromorphic communication protocol for transferring information of spiking neurons implemented into VLSI chips. These neuro-inspired implementations have been used to design sensor chips (retina, cochleas), processing chips (convolutions, filters) and learning chips, what makes possible the development of complex, multilayer, multichip neuromorphic systems. In biology one of the last steps of the processing is to move a muscle, to apply the results of these complex neuromorphic processing to the real world. One interesting question is to be able to transform, or translate, the AER information into robot movements, like for example, moving a DC motor. This paper presents several ways to translate AER spikes into DC motor power, and to control a DC motor speed, based on Pulse Frequency Modulation. These methods have been simulated into Simulink with Xilinx System Generator, and tested into the AER-Robot platform.Junta de Andalucía P06-TIC-01417Ministerio de Educación y Ciencia TEC2006-11730-C03-0

    From Vision Sensor to Actuators, Spike Based Robot Control through Address-Event-Representation

    Get PDF
    One field of the neuroscience is the neuroinformatic whose aim is to develop auto-reconfigurable systems that mimic the human body and brain. In this paper we present a neuro-inspired spike based mobile robot. From commercial cheap vision sensors converted into spike information, through spike filtering for object recognition, to spike based motor control models. A two wheel mobile robot powered by DC motors can be autonomously controlled to follow a line drown in the floor. This spike system has been developed around the well-known Address-Event-Representation mechanism to communicate the different neuro-inspired layers of the system. RTC lab has developed all the components presented in this work, from the vision sensor, to the robot platform and the FPGA based platforms for AER processing.Ministerio de Ciencia e Innovación TEC2006-11730-C03-02Junta de Andalucía P06-TIC-0141

    Spike Processing on an Embedded Multi-task Computer: Image Reconstruction

    Get PDF
    There is an emerging philosophy, called Neuro-informatics, contained in the Artificial Intelligence field, that aims to emulate how living beings do tasks such as taking a decision based on the interpretation of an image by emulating spiking neurons into VLSI designs and, therefore, trying to re-create the human brain at its highest level. Address-Event-Representation (AER) is a communication protocol that has embedded part of the processing. It is intended to transfer spikes between bioinspired chips. An AER based system may consist of a hierarchical structure with several chips that transmit spikes among them in real-time, while performing some processing. There are several AER tools to help to develop and test AER based systems. These tools require the use of a computer to allow the higher level processing of the event information, reaching very high bandwidth at the AER communication level. We propose the use of an embedded platform based on a multi-task operating system to allow both, the AER communication and processing without the requirement of either a laptop or a computer. In this paper, we present and study the performance of a new philosophy of a frame-grabber AER tool based on a multi-task environment. This embedded platform is based on the Intel XScale processor which is governed by an embedded GNU/Linux system. We have connected and programmed it for processing Address-Event information from a spiking generator.Ministerio de Educación y Ciencia TEC2006-11730-C03-0

    A Real-Time Wireless Sensor Network for Wheelchair Navigation

    Get PDF
    Today, the availability of inexpensive, low power hardware including CMOS cameras and wireless devices make it possible to deploy a wireless sensor network (WSN) with nodes equipped with cameras for a variety of applications. In this paper, we discuss the use of one of these WSNs as a navigation aid for wheelchairs. Instead of having complicated wheelchairs with lots of on-board sensors, we argue that a viable alternative is to have simpler wheelchairs that are able to interact with an intelligent environment so that the wheelchair bases its navigation on its software intelligence, supported by the information sent by external sensors. Many questions have to be investigated, for instance how sensors should be deployed or whether the wireless links would be able to meet our temporal requirements. We describe some of the solutions we adopted, particularly how to implement with Zigbee devices a polling mechanism that allows us to guarantee a real-time secure navigation.Ministerio de Educación y Ciencia TIN2006-15617- C03-03Junta de Andalucía P06-TIC-229

    Crustal-scale transcurrent fault development in a weak-layered crust from an integrated geophysical research: Carboneras Fault Zone, eastern Betic Cordillera, Spain

    No full text
    International audienceNew magnetotelluric and receiver transfer function studies provide insights from the upper to the lower crust of the eastern Betic Cordillera, which is deformed by large folds, normal faults, and a major transcurrent left-lateral fault, the Carboneras Fault Zone (CFZ). Receiver function analysis determines a NNW dipping Moho reaching 20 degrees that increases in depth, from 20 km south of the CFZ up to 34 km in the Sierra de Los Filabres. In addition, seismic discontinuities determined in the upper crust are interpreted as major contacts between metamorphic complexes that are detached and folded. The MT inversion model reveals a conductive zone, also representing a crustal seismic discontinuity, associated with the Alpujarride/Nevado-Filabride contact and fitting the N vergent geometry of the Sierra Alhamilla antiform. A small flexure at Moho coincides with the CFZ, as revealed by the Bouguer anomaly trend, in agreement with the receiver function results. Moreover, the Bahr strike and tipper angle at the stations placed closest to the CFZ clearly reveal the continuity of the CFZ at least down to approximately 15 km in depth, crossing all the detected crustal discontinuities up to the Moho. The lack of a clear Moho offset associated with the Carboneras Fault supports the idea that some large strike-slip faults tend to accommodate the deformation by a broadening fault zone at lower crustal levels. Its nucleation could occur at the base of a thin crust, where melting processes critically reduced the lithospheric strength during the late Miocene, to then propagate upward, reaching the topographic surface. Northward, the lithosphere comprised moderately larger strength, and the crustal discontinuities favored the development of larger folds with kilometric amplitude instead of strike-slip faults since the late Miocene

    Libro de Proyectos Finales 2021 primer semestre

    No full text
    PregradoIngeniero CivilIngeniero de SistemasIngeniero ElectricistaIngeniero ElectrónicoIngeniero IndustrialIngeniero Mecánic

    Ilustración arqueológica en los Andes (1850-1890)

    No full text

    Global attitudes in the management of acute appendicitis during COVID-19 pandemic: ACIE Appy Study

    No full text
    Background: Surgical strategies are being adapted to face the COVID-19 pandemic. Recommendations on the management of acute appendicitis have been based on expert opinion, but very little evidence is available. This study addressed that dearth with a snapshot of worldwide approaches to appendicitis. Methods: The Association of Italian Surgeons in Europe designed an online survey to assess the current attitude of surgeons globally regarding the management of patients with acute appendicitis during the pandemic. Questions were divided into baseline information, hospital organization and screening, personal protective equipment, management and surgical approach, and patient presentation before versus during the pandemic. Results: Of 744 answers, 709 (from 66 countries) were complete and were included in the analysis. Most hospitals were treating both patients with and those without COVID. There was variation in screening indications and modality used, with chest X-ray plus molecular testing (PCR) being the commonest (19\ub78 per cent). Conservative management of complicated and uncomplicated appendicitis was used by 6\ub76 and 2\ub74 per cent respectively before, but 23\ub77 and 5\ub73 per cent, during the pandemic (both P < 0\ub7001). One-third changed their approach from laparoscopic to open surgery owing to the popular (but evidence-lacking) advice from expert groups during the initial phase of the pandemic. No agreement on how to filter surgical smoke plume during laparoscopy was identified. There was an overall reduction in the number of patients admitted with appendicitis and one-third felt that patients who did present had more severe appendicitis than they usually observe. Conclusion: Conservative management of mild appendicitis has been possible during the pandemic. The fact that some surgeons switched to open appendicectomy may reflect the poor guidelines that emanated in the early phase of SARS-CoV-2

    Global variation in postoperative mortality and complications after cancer surgery: a multicentre, prospective cohort study in 82 countries

    No full text
    © 2021 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 licenseBackground: 80% of individuals with cancer will require a surgical procedure, yet little comparative data exist on early outcomes in low-income and middle-income countries (LMICs). We compared postoperative outcomes in breast, colorectal, and gastric cancer surgery in hospitals worldwide, focusing on the effect of disease stage and complications on postoperative mortality. Methods: This was a multicentre, international prospective cohort study of consecutive adult patients undergoing surgery for primary breast, colorectal, or gastric cancer requiring a skin incision done under general or neuraxial anaesthesia. The primary outcome was death or major complication within 30 days of surgery. Multilevel logistic regression determined relationships within three-level nested models of patients within hospitals and countries. Hospital-level infrastructure effects were explored with three-way mediation analyses. This study was registered with ClinicalTrials.gov, NCT03471494. Findings: Between April 1, 2018, and Jan 31, 2019, we enrolled 15 958 patients from 428 hospitals in 82 countries (high income 9106 patients, 31 countries; upper-middle income 2721 patients, 23 countries; or lower-middle income 4131 patients, 28 countries). Patients in LMICs presented with more advanced disease compared with patients in high-income countries. 30-day mortality was higher for gastric cancer in low-income or lower-middle-income countries (adjusted odds ratio 3·72, 95% CI 1·70–8·16) and for colorectal cancer in low-income or lower-middle-income countries (4·59, 2·39–8·80) and upper-middle-income countries (2·06, 1·11–3·83). No difference in 30-day mortality was seen in breast cancer. The proportion of patients who died after a major complication was greatest in low-income or lower-middle-income countries (6·15, 3·26–11·59) and upper-middle-income countries (3·89, 2·08–7·29). Postoperative death after complications was partly explained by patient factors (60%) and partly by hospital or country (40%). The absence of consistently available postoperative care facilities was associated with seven to 10 more deaths per 100 major complications in LMICs. Cancer stage alone explained little of the early variation in mortality or postoperative complications. Interpretation: Higher levels of mortality after cancer surgery in LMICs was not fully explained by later presentation of disease. The capacity to rescue patients from surgical complications is a tangible opportunity for meaningful intervention. Early death after cancer surgery might be reduced by policies focusing on strengthening perioperative care systems to detect and intervene in common complications. Funding: National Institute for Health Research Global Health Research Unit
    corecore